[EMAIL PROTECTED] wrote: > On Fri, 12 Oct 2007 09:35:15 PDT, "Kok, Auke" said: > >>> How much power does a non-connected NIC consume, and can you save power >>> by forcing 10 MBit until a link is detected (doubling negotiation time)? >> no, the PHY consumes a minimal amount of energy when not connected, >> regardless of >> whether it is advertising 10, 100 or 1000mbit. > > Is that true for essentially all the chipsets we support (or at least "the > vast > majority of the ones currently found in common machines")?
I would assume that that is true for all PHY's - if there is no link to keep the carrier active on I would think that the power consumption is nominal across the board. Once the PHY detects link pulses it should obviously use different power levels to negotiate the link for each speed. PHY autonegotiation just works the same across the board - the PHY's send out little pulses (iow nominal power consumption) to detect a link partner, and only when one is found do they engage in more aggressive conversation to establish capabilities across the link. Auke - To unsubscribe from this list: send the line "unsubscribe linux-kernel" in the body of a message to [EMAIL PROTECTED] More majordomo info at http://vger.kernel.org/majordomo-info.html Please read the FAQ at http://www.tux.org/lkml/