On 24/06/2020 18:15, Neil Armstrong wrote: > The new Khadas VIM2 and VIM3 boards controls the cooling fan via the > on-board microcontroller. > > This implements the FAN control as thermal devices and as cell of the Khadas > MCU MFD driver. > > Signed-off-by: Neil Armstrong <narmstr...@baylibre.com> > Reviewed-by: Amit Kucheria <amit.kuche...@linaro.org> > --- > Hi Daniel, > > Is it ok Lee applies this patch via the MFD tree since it depends on > the linux/mfd/khadas-mcu.h header ?
Acked-by: Daniel Lezcano <daniel.lezc...@linaro.org> [ ... ] -- <http://www.linaro.org/> Linaro.org │ Open source software for ARM SoCs Follow Linaro: <http://www.facebook.com/pages/Linaro> Facebook | <http://twitter.com/#!/linaroorg> Twitter | <http://www.linaro.org/linaro-blog/> Blog