On 22.07.20 12:22, Stefano Garzarella wrote:
Commit ed66f991bb19 ("module: Refactor section attr into bin
attribute") removed the 'name' field from 'struct module_sect_attr'
triggering the following error when invoking lx-symbols:

   (gdb) lx-symbols
   loading vmlinux
   scanning for modules in linux/build
   loading @0xffffffffc014f000: linux/build/drivers/net/tun.ko
   Python Exception <class 'gdb.error'> There is no member named name.:
   Error occurred in Python: There is no member named name.

This patch fixes the issue taking the module name from the 'struct
attribute'.

Signed-off-by: Stefano Garzarella <sgarz...@redhat.com>
---
  scripts/gdb/linux/symbols.py | 2 +-
  1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/scripts/gdb/linux/symbols.py b/scripts/gdb/linux/symbols.py
index be984aa29b75..1be9763cf8bb 100644
--- a/scripts/gdb/linux/symbols.py
+++ b/scripts/gdb/linux/symbols.py
@@ -96,7 +96,7 @@ lx-symbols command."""
              return ""
          attrs = sect_attrs['attrs']
          section_name_to_address = {
-            attrs[n]['name'].string(): attrs[n]['address']
+            attrs[n]['battr']['attr']['name'].string(): attrs[n]['address']
              for n in range(int(sect_attrs['nsections']))}
          args = []
          for section_name in [".data", ".data..read_mostly", ".rodata", ".bss",


Reviewed-by: Jan Kiszka <jan.kis...@siemens.com>

Thanks,
Jan

--
Siemens AG, Corporate Technology, CT RDA IOT SES-DE
Corporate Competence Center Embedded Linux

Reply via email to