Hi,

On 7/23/20 9:06 PM, Stanimir Varbanov wrote:
> Hi Rajendra,
> 
> After applying 2,3 and 4/5 patches on linaro-integration v5.8-rc2 I see
> below messages on db845:
> 
> qcom-venus aa00000.video-codec: dev_pm_opp_set_rate: failed to find
> current OPP for freq 533000097 (-34)
> 
> ^^^ This one is new.
> 
> qcom_rpmh TCS Busy, retrying RPMH message send: addr=0x30000
> 
> ^^^ and this message is annoying, can we make it pr_debug in rpmh?
> 
> On 7/23/20 2:26 PM, Rajendra Nayak wrote:
>> Add the OPP tables in order to be able to vote on the performance state of
>> a power-domain.
>>
>> Signed-off-by: Rajendra Nayak <rna...@codeaurora.org>
>> ---
>>  arch/arm64/boot/dts/qcom/sdm845.dtsi | 40 
>> ++++++++++++++++++++++++++++++++++--
>>  1 file changed, 38 insertions(+), 2 deletions(-)
>>
>> diff --git a/arch/arm64/boot/dts/qcom/sdm845.dtsi 
>> b/arch/arm64/boot/dts/qcom/sdm845.dtsi
>> index e506793..5ca2265 100644
>> --- a/arch/arm64/boot/dts/qcom/sdm845.dtsi
>> +++ b/arch/arm64/boot/dts/qcom/sdm845.dtsi
>> @@ -3631,8 +3631,10 @@
>>                      interrupts = <GIC_SPI 174 IRQ_TYPE_LEVEL_HIGH>;
>>                      power-domains = <&videocc VENUS_GDSC>,
>>                                      <&videocc VCODEC0_GDSC>,
>> -                                    <&videocc VCODEC1_GDSC>;
>> -                    power-domain-names = "venus", "vcodec0", "vcodec1";
>> +                                    <&videocc VCODEC1_GDSC>,
>> +                                    <&rpmhpd SDM845_CX>;
>> +                    power-domain-names = "venus", "vcodec0", "vcodec1", 
>> "cx";
>> +                    operating-points-v2 = <&venus_opp_table>;
>>                      clocks = <&videocc VIDEO_CC_VENUS_CTL_CORE_CLK>,
>>                               <&videocc VIDEO_CC_VENUS_AHB_CLK>,
>>                               <&videocc VIDEO_CC_VENUS_CTL_AXI_CLK>,
>> @@ -3654,6 +3656,40 @@
>>                      video-core1 {
>>                              compatible = "venus-encoder";
>>                      };
>> +
>> +                    venus_opp_table: venus-opp-table {
>> +                            compatible = "operating-points-v2";
>> +
>> +                            opp-100000000 {
>> +                                    opp-hz = /bits/ 64 <100000000>;
>> +                                    required-opps = <&rpmhpd_opp_min_svs>;
>> +                            };
>> +
>> +                            opp-200000000 {
>> +                                    opp-hz = /bits/ 64 <200000000>;
>> +                                    required-opps = <&rpmhpd_opp_low_svs>;
>> +                            };
>> +
>> +                            opp-320000000 {
>> +                                    opp-hz = /bits/ 64 <320000000>;
>> +                                    required-opps = <&rpmhpd_opp_svs>;
>> +                            };
>> +
>> +                            opp-380000000 {
>> +                                    opp-hz = /bits/ 64 <380000000>;
>> +                                    required-opps = <&rpmhpd_opp_svs_l1>;
>> +                            };
>> +
>> +                            opp-444000000 {
>> +                                    opp-hz = /bits/ 64 <444000000>;
>> +                                    required-opps = <&rpmhpd_opp_nom>;
>> +                            };
>> +
>> +                            opp-533000000 {
>> +                                    opp-hz = /bits/ 64 <533000000>;

Actually it comes from videocc, where ftbl_video_cc_venus_clk_src
defines 533000000 but the real calculated freq is 533000097.

If I change to opp-hz = /bits/ 64 <533000097> the error disappear.

I guess we have to revisit m/n and/or pre-divider for this freq when the
source pll is P_VIDEO_PLL0_OUT_MAIN PLL?

>> +                                    required-opps = <&rpmhpd_opp_turbo>;
>> +                            };
>> +                    };
>>              };
>>  
>>              videocc: clock-controller@ab00000 {
>>
> 

-- 
regards,
Stan

Reply via email to