On 24.08.20 13:44, Vignesh Raghavendra wrote:
> Hi Jan,
> 
> On 8/24/20 11:25 AM, Jan Kiszka wrote:
> [...]
> 
>>> +MODULE_AUTHOR("Vignesh Raghavendra <vigne...@ti.com>");
>>>
>> On the AM65x, this changes mtd->name (thus mtd-id for
>> parser/cmdlinepart) from 47040000.spi.0 to spi7.0. The besides having to
>> deal with both names now, "spi7" sounds like it could easily change
>> again if someone plugs or unplugs some other SPI device. Is this intended?
>>
> 
> You could use DT aliases to make sure OSPI0 is always at given bus num
> (say spi7):
> 
>         aliases {
>                 spi7 = &ospi0;
>         };

Ah, looks like this is a common pattern... Thanks, will try that.