From: Marek Vasut <ma...@denx.de>

[ Upstream commit 0da1ccbbefb662915228bc17e1c7d4ad28b3ddab ]

The phy_reset_after_clk_enable() does a PHY reset, which means the PHY
loses its register settings. The fec_enet_mii_probe() starts the PHY
and does the necessary calls to configure the PHY via PHY framework,
and loads the correct register settings into the PHY. Therefore,
fec_enet_mii_probe() should be called only after the PHY has been
reset, not before as it is now.

Fixes: 1b0a83ac04e3 ("net: fec: add phy_reset_after_clk_enable() support")
Reviewed-by: Andrew Lunn <and...@lunn.ch>
Tested-by: Richard Leitner <richard.leit...@skidata.com>
Signed-off-by: Marek Vasut <ma...@denx.de>
Cc: Christoph Niedermaier <cniederma...@dh-electronics.com>
Cc: David S. Miller <da...@davemloft.net>
Cc: NXP Linux Team <linux-...@nxp.com>
Cc: Shawn Guo <shawn...@kernel.org>
Signed-off-by: Jakub Kicinski <k...@kernel.org>
Signed-off-by: Greg Kroah-Hartman <gre...@linuxfoundation.org>
---
 drivers/net/ethernet/freescale/fec_main.c |   10 +++++-----
 1 file changed, 5 insertions(+), 5 deletions(-)

--- a/drivers/net/ethernet/freescale/fec_main.c
+++ b/drivers/net/ethernet/freescale/fec_main.c
@@ -2950,17 +2950,17 @@ fec_enet_open(struct net_device *ndev)
        /* Init MAC prior to mii bus probe */
        fec_restart(ndev);
 
-       /* Probe and connect to PHY when open the interface */
-       ret = fec_enet_mii_probe(ndev);
-       if (ret)
-               goto err_enet_mii_probe;
-
        /* Call phy_reset_after_clk_enable() again if it failed during
         * phy_reset_after_clk_enable() before because the PHY wasn't probed.
         */
        if (reset_again)
                fec_enet_phy_reset_after_clk_enable(ndev);
 
+       /* Probe and connect to PHY when open the interface */
+       ret = fec_enet_mii_probe(ndev);
+       if (ret)
+               goto err_enet_mii_probe;
+
        if (fep->quirks & FEC_QUIRK_ERR006687)
                imx6q_cpuidle_fec_irqs_used();
 