On 22/10/2020 08:44, peng....@nxp.com wrote:
From: Peng Fan <peng....@nxp.com> When offset is not 4 bytes aligned, directly shift righty by 2 bits will cause reading out wrong data. Since imx ocotp only supports 4 bytes reading once, we need handle offset is not 4 bytes aligned and enlarge the bytes to 4 bytes aligned. After reading finished, copy the needed data from buffer to caller and free buffer. Signed-off-by: Peng Fan <peng....@nxp.com>
Applied thanks, srini