On 21/12/2020 19:13, Martin Blumenstingl wrote:
> The SoC temperature can be retrieved from ADC channel 8 on all 32-bit
> SoCs (Meson6, Meson8, Meson8b and Meson8m2). Add a "generic-adc-thermal"
> instance to meson.dtsi so the thermal sensor is available for all SoCs.
> If the temperature sensor calibration data is missing for a board then
> the "generic-adc-thermal" will not probe and not register a thermal
> sensor.
> 
> Signed-off-by: Martin Blumenstingl <[email protected]>
> ---
>  arch/arm/boot/dts/meson.dtsi | 7 +++++++
>  1 file changed, 7 insertions(+)
> 
> diff --git a/arch/arm/boot/dts/meson.dtsi b/arch/arm/boot/dts/meson.dtsi
> index 5f074f7aa1a2..e0ca5f08d07d 100644
> --- a/arch/arm/boot/dts/meson.dtsi
> +++ b/arch/arm/boot/dts/meson.dtsi
> @@ -298,6 +298,13 @@ efuse: nvmem@0 {
>               };
>       };
>  
> +     thermal_sensor: thermal-sensor {
> +             compatible = "generic-adc-thermal";
> +             #thermal-sensor-cells = <0>;
> +             io-channels = <&saradc 8>;
> +             io-channel-names = "sensor-channel";
> +     };
> +
>       xtal: xtal-clk {
>               compatible = "fixed-clock";
>               clock-frequency = <24000000>;
> 

Reviewed-by: Neil Armstrong <[email protected]>

Reply via email to