On Fri, 08 Jan 2021 17:30:04 +0100, Jonathan Neuschäfer wrote:
> The NPCM750 Timer/Watchdog Controller has multiple interrupt lines,
> connected to multiple timers. The driver uses timer 0 for timer
> interrupts, so the interrupt line corresponding to timer 0 should be
> specified in DT.
> 
> I removed the mention of "flags for falling edge", because the timer
> controller uses high-level interrupts rather than falling-edge
> interrupts, and whether flags should be specified is up the interrupt
> controller's DT binding.
> 
> Signed-off-by: Jonathan Neuschäfer <[email protected]>
> ---
> 
> v2:
> - Fix a typo in the word "watchdog"
> ---
>  .../devicetree/bindings/timer/nuvoton,npcm7xx-timer.txt        | 3 +--
>  1 file changed, 1 insertion(+), 2 deletions(-)
> 

Acked-by: Rob Herring <[email protected]>