Fix start and stop conversion commands.  The proper command is not be
sent.

Fixes: ("e717f8c6dfec iio: adc: Add the TI ads124s08 ADC code")
Signed-off-by: Dan Murphy <dmur...@ti.com>
---
 drivers/iio/adc/ti-ads124s08.c | 4 ++--
 1 file changed, 2 insertions(+), 2 deletions(-)

diff --git a/drivers/iio/adc/ti-ads124s08.c b/drivers/iio/adc/ti-ads124s08.c
index b4a128b19188..f05d4e0e1c9d 100644
--- a/drivers/iio/adc/ti-ads124s08.c
+++ b/drivers/iio/adc/ti-ads124s08.c
@@ -237,7 +237,7 @@ static int ads124s_read_raw(struct iio_dev *indio_dev,
                        goto out;
                }
 
-               ret = ads124s_write_cmd(indio_dev, ADS124S08_START_CONV);
+               ret = ads124s_write_cmd(indio_dev, ADS124S08_CMD_START);
                if (ret) {
                        dev_err(&priv->spi->dev, "Start conversions failed\n");
                        goto out;
@@ -251,7 +251,7 @@ static int ads124s_read_raw(struct iio_dev *indio_dev,
 
                *val = ret;
 
-               ret = ads124s_write_cmd(indio_dev, ADS124S08_STOP_CONV);
+               ret = ads124s_write_cmd(indio_dev, ADS124S08_CMD_STOP);
                if (ret) {
                        dev_err(&priv->spi->dev, "Stop conversions failed\n");
                        goto out;
-- 
2.29.2