22.01.2021 16:40, Mark Brown пишет:
> On Fri, Jan 22, 2021 at 01:16:49AM +0300, Dmitry Osipenko wrote:
> 
>> +    /* balance only if there are regulators coupled */
>> +    if (rdev->coupling_desc.n_coupled > 1) {
>> +            ret = regulator_balance_voltage(rdev, PM_SUSPEND_ON);
>> +            goto out;
>> +    }
>> +
>>      ret = _regulator_do_set_voltage(rdev, min_uV, max_uV);
>>  
>>  out:
> 
> This would be clearer written as an if/else rather than using the goto.
> 

I'll make v4, thanks.

Reply via email to