> On Sun, Jan 24, 2021 at 01:43:57PM +0200, stef...@marvell.com wrote:
> > +/* Set Flow Control timer x140 faster than pause quanta to ensure
> > +that link
> > + * partner won't send taffic if port in XOFF mode.
> 
> Can you explain more why 140 times faster is desirable here? Why 140 times
> and not, say, 10 times faster? Where does this figure come from, and what is
> the reasoning? Is there a switch that requires it?

I tested with 140.
Actually regarding to spec each quanta should be equal to 512 bit times.
In 10G bit time is 0.1ns.
So It actually should be:
FC_CLK_DIVIDER = 10000 / 512 = ~20. I took some buffer and made it 140.
So maybe I can do it 100?

Regards,
Stefan.

Reply via email to