BD9576MUF provides over-current protection and detection. Current is
measured as voltage loss over external FET. Allow specifying FET's on
resistance so current monitoring limits can be converted to voltages.

Signed-off-by: Matti Vaittinen <matti.vaitti...@fi.rohmeurope.com>
---
 .../devicetree/bindings/regulator/rohm,bd9576-regulator.yaml | 5 +++++
 1 file changed, 5 insertions(+)

diff --git 
a/Documentation/devicetree/bindings/regulator/rohm,bd9576-regulator.yaml 
b/Documentation/devicetree/bindings/regulator/rohm,bd9576-regulator.yaml
index b6515a0cee62..ad3f57e9cd9b 100644
--- a/Documentation/devicetree/bindings/regulator/rohm,bd9576-regulator.yaml
+++ b/Documentation/devicetree/bindings/regulator/rohm,bd9576-regulator.yaml
@@ -27,6 +27,11 @@ patternProperties:
       Properties for single regulator.
     $ref: "regulator.yaml#"
 
+    properties:
+      rohm,ocw-fet-ron-milliohms:
+      description: External FET's ON-resistance. Required if VoutS1 OCP/OCW is
+        to be set.
+
     required:
       - regulator-name
 
-- 
2.25.4


-- 
Matti Vaittinen, Linux device drivers