On 16-03-21, 10:12, Kuogee Hsieh wrote:
> Add hbr3_hbr2 voltage and premphasis swing table to support
> HBR3 link rate.
> 
> Changes in V2:
> -- replaced upper case with lower case at hbr3_hbr2 table
> 
> Changes in v3:
> -- replace space with tab at hbr3_hbr2 table

This should be after the --- line below
> 
> Signed-off-by: Kuogee Hsieh <khs...@codeaurora.org>

No need of blank line here
> 
> Reviewed-by: Stephen Boyd <swb...@chromium.org>

I took the liberty of fixing these two, applying the fixes tag and
applied..


-- 
~Vinod