On Thu, 25 Feb 2021 14:33:20 +0100, Heiko Stuebner wrote: > The vendor-kernel did increase the minimum voltage for some low frequency > opps to 825mV citing stability reasons. So do that in mainline as well > and also use the ranged notation the vendor-kernel switched to, to give > a bit more flexibility for different regulator setups.
Applied, thanks! [1/3] arm64: dts: rockchip: synchronize rk3399 opps with vendor kernel commit: 6daae8ff20b8e9d67c282ba37c63e1a7ee3c2206 [2/3] arm64: dts: rockchip: used range'd gpu opps on rk3399 commit: 6d5989a36e60614e12949c6c2dac368b380bf2ca [3/3] arm64: dts: rockchip: drop separate opp table on rk3399-puma commit: b417764daa2d7e1325fe926144ffcb4b2bbd8d25 Best regards, -- Heiko Stuebner <he...@sntech.de>