Hi Eric,

On 2021/2/24 4:56, Eric Auger wrote:
+static int
+arm_smmu_cache_invalidate(struct iommu_domain *domain, struct device *dev,
+                         struct iommu_cache_invalidate_info *inv_info)
+{
+       struct arm_smmu_cmdq_ent cmd = {.opcode = CMDQ_OP_TLBI_NSNH_ALL};
+       struct arm_smmu_domain *smmu_domain = to_smmu_domain(domain);
+       struct arm_smmu_device *smmu = smmu_domain->smmu;
+
+       if (smmu_domain->stage != ARM_SMMU_DOMAIN_NESTED)
+               return -EINVAL;
+
+       if (!smmu)
+               return -EINVAL;
+
+       if (inv_info->version != IOMMU_CACHE_INVALIDATE_INFO_VERSION_1)
+               return -EINVAL;
+
+       if (inv_info->cache & IOMMU_CACHE_INV_TYPE_PASID ||

I didn't find any code where we would emulate the CFGI_CD{_ALL} commands
for guest and invalidate the stale CD entries on the physical side. Is
PASID-cache type designed for that effect?

+           inv_info->cache & IOMMU_CACHE_INV_TYPE_DEV_IOTLB) {
+               return -ENOENT;
+       }
+
+       if (!(inv_info->cache & IOMMU_CACHE_INV_TYPE_IOTLB))
+               return -EINVAL;
+
+       /* IOTLB invalidation */
+
+       switch (inv_info->granularity) {
+       case IOMMU_INV_GRANU_PASID:
+       {
+               struct iommu_inv_pasid_info *info =
+                       &inv_info->granu.pasid_info;
+
+               if (info->flags & IOMMU_INV_ADDR_FLAGS_PASID)
+                       return -ENOENT;
+               if (!(info->flags & IOMMU_INV_PASID_FLAGS_ARCHID))
+                       return -EINVAL;
+
+               __arm_smmu_tlb_inv_context(smmu_domain, info->archid);
+               return 0;
+       }
+       case IOMMU_INV_GRANU_ADDR:
+       {
+               struct iommu_inv_addr_info *info = &inv_info->granu.addr_info;
+               size_t size = info->nb_granules * info->granule_size;
+               bool leaf = info->flags & IOMMU_INV_ADDR_FLAGS_LEAF;
+
+               if (info->flags & IOMMU_INV_ADDR_FLAGS_PASID)
+                       return -ENOENT;
+
+               if (!(info->flags & IOMMU_INV_ADDR_FLAGS_ARCHID))
+                       break;
+
+               arm_smmu_tlb_inv_range_domain(info->addr, size,
+                                             info->granule_size, leaf,
+                                             info->archid, smmu_domain);
+
+               arm_smmu_cmdq_issue_sync(smmu);

There is no need to issue one more SYNC.

Reply via email to