On 4/1/21 11:36 AM, Andy Shevchenko wrote:
[...]
+       case IIO_CHAN_INFO_SCALE:
+               /* Conversion from 10s of uC to mC
+                * as IIO reports temperature in mC
+                */
+               *val = TMP117_RESOLUTION_10UC / 10000;
+               *val2 = (TMP117_RESOLUTION_10UC % 10000) * 100;
+               return IIO_VAL_INT_PLUS_MICRO;
You use 10000 many times, can you give it an appropriate name (via #define)?
#define TENTHOUSAND 10000 ;)