From: Richard Gong <[email protected]>
[ Upstream commit 2e8496f31d0be8f43849b2980b069f3a9805d047 ]
Clean up COMMAND_RECONFIG_FLAG_PARTIAL flag by resetting it to 0, which
aligns with the firmware settings.
Fixes: 36847f9e3e56 ("firmware: stratix10-svc: correct reconfig flag and
timeout values")
Signed-off-by: Richard Gong <[email protected]>
Reviewed-by: Tom Rix <[email protected]>
Signed-off-by: Moritz Fischer <[email protected]>
Signed-off-by: Sasha Levin <[email protected]>
---
include/linux/firmware/intel/stratix10-svc-client.h | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/include/linux/firmware/intel/stratix10-svc-client.h
b/include/linux/firmware/intel/stratix10-svc-client.h
index a93d85932eb9..f843c6a10cf3 100644
--- a/include/linux/firmware/intel/stratix10-svc-client.h
+++ b/include/linux/firmware/intel/stratix10-svc-client.h
@@ -56,7 +56,7 @@
* COMMAND_RECONFIG_FLAG_PARTIAL:
* Set to FPGA configuration type (full or partial).
*/
-#define COMMAND_RECONFIG_FLAG_PARTIAL 1
+#define COMMAND_RECONFIG_FLAG_PARTIAL 0
/**
* Timeout settings for service clients:
--
2.30.2