Hi Maintainers,

Gentle pin for this patch.

Thanks

On Tue, 2021-03-16 at 15:01 +0800, Michael Kao wrote:
> Provide thermal zone to read thermal sensor
> in the SoC. We can read all the thermal sensors
> value in the SoC by the node /sys/class/thermal/
> 
> In mtk_thermal_bank_temperature, return -EAGAIN instead of -EACCESS
> on the first read of sensor that often are bogus values.
> This can avoid following warning on boot:
> 
>   thermal thermal_zone6: failed to read out thermal zone (-13)
> 
> Signed-off-by: Michael Kao <michael....@mediatek.com>
> Signed-off-by: Hsin-Yi Wang <hsi...@chromium.org>
> ---
>  drivers/thermal/mtk_thermal.c | 100 +++++++++++++++++++++++++---------
>  1 file changed, 75 insertions(+), 25 deletions(-)
> 
> diff --git a/drivers/thermal/mtk_thermal.c b/drivers/thermal/mtk_thermal.c
> index 149c6d7fd5a0..57e4f08a947e 100644
> --- a/drivers/thermal/mtk_thermal.c
> +++ b/drivers/thermal/mtk_thermal.c
> @@ -245,6 +245,11 @@ enum mtk_thermal_version {
>  
>  struct mtk_thermal;
>  
> +struct mtk_thermal_zone {
> +     struct mtk_thermal *mt;
> +     int id;
> +};
> +
>  struct thermal_bank_cfg {
>       unsigned int num_sensors;
>       const int *sensors;
> @@ -637,6 +642,30 @@ static void mtk_thermal_put_bank(struct mtk_thermal_bank 
> *bank)
>               mutex_unlock(&mt->lock);
>  }
>  
> +static u32 _get_sensor_temp(struct mtk_thermal *mt, int id)
> +{
> +     u32 raw;
> +     int temp;
> +
> +     raw = readl(mt->thermal_base + mt->conf->msr[id]);
> +
> +     if (mt->conf->version == MTK_THERMAL_V1)
> +             temp = raw_to_mcelsius_v1(mt, id, raw);
> +     else
> +             temp = raw_to_mcelsius_v2(mt, id, raw);
> +
> +     /*
> +      * The first read of a sensor often contains very high bogus
> +      * temperature value. Filter these out so that the system does
> +      * not immediately shut down.
> +      */
> +
> +     if (temp > 200000)
> +             return -EAGAIN;
> +     else
> +             return temp;
> +}
> +
>  /**
>   * mtk_thermal_bank_temperature - get the temperature of a bank
>   * @bank:    The bank
> @@ -647,28 +676,11 @@ static void mtk_thermal_put_bank(struct 
> mtk_thermal_bank *bank)
>  static int mtk_thermal_bank_temperature(struct mtk_thermal_bank *bank)
>  {
>       struct mtk_thermal *mt = bank->mt;
> -     const struct mtk_thermal_data *conf = mt->conf;
>       int i, temp = INT_MIN, max = INT_MIN;
> -     u32 raw;
> -
> -     for (i = 0; i < conf->bank_data[bank->id].num_sensors; i++) {
> -             raw = readl(mt->thermal_base + conf->msr[i]);
>  
> -             if (mt->conf->version == MTK_THERMAL_V1) {
> -                     temp = raw_to_mcelsius_v1(
> -                             mt, conf->bank_data[bank->id].sensors[i], raw);
> -             } else {
> -                     temp = raw_to_mcelsius_v2(
> -                             mt, conf->bank_data[bank->id].sensors[i], raw);
> -             }
> +     for (i = 0; i < mt->conf->bank_data[bank->id].num_sensors; i++) {
>  
> -             /*
> -              * The first read of a sensor often contains very high bogus
> -              * temperature value. Filter these out so that the system does
> -              * not immediately shut down.
> -              */
> -             if (temp > 200000)
> -                     temp = 0;
> +             temp = _get_sensor_temp(mt, i);
>  
>               if (temp > max)
>                       max = temp;
> @@ -679,7 +691,8 @@ static int mtk_thermal_bank_temperature(struct 
> mtk_thermal_bank *bank)
>  
>  static int mtk_read_temp(void *data, int *temperature)
>  {
> -     struct mtk_thermal *mt = data;
> +     struct mtk_thermal_zone *tz = data;
> +     struct mtk_thermal *mt = tz->mt;
>       int i;
>       int tempmax = INT_MIN;
>  
> @@ -698,10 +711,28 @@ static int mtk_read_temp(void *data, int *temperature)
>       return 0;
>  }
>  
> +static int mtk_read_sensor_temp(void *data, int *temperature)
> +{
> +     struct mtk_thermal_zone *tz = data;
> +     struct mtk_thermal *mt = tz->mt;
> +     int id = tz->id - 1;
> +
> +     if (id < 0)
> +             return -EACCES;
> +
> +     *temperature = _get_sensor_temp(mt, id);
> +
> +     return 0;
> +}
> +
>  static const struct thermal_zone_of_device_ops mtk_thermal_ops = {
>       .get_temp = mtk_read_temp,
>  };
>  
> +static const struct thermal_zone_of_device_ops mtk_thermal_sensor_ops = {
> +     .get_temp = mtk_read_sensor_temp,
> +};
> +
>  static void mtk_thermal_init_bank(struct mtk_thermal *mt, int num,
>                                 u32 apmixed_phys_base, u32 auxadc_phys_base,
>                                 int ctrl_id)
> @@ -992,6 +1023,7 @@ static int mtk_thermal_probe(struct platform_device 
> *pdev)
>       u64 auxadc_phys_base, apmixed_phys_base;
>       struct thermal_zone_device *tzdev;
>       void __iomem *apmixed_base, *auxadc_base;
> +     struct mtk_thermal_zone *tz;
>  
>       mt = devm_kzalloc(&pdev->dev, sizeof(*mt), GFP_KERNEL);
>       if (!mt)
> @@ -1080,11 +1112,29 @@ static int mtk_thermal_probe(struct platform_device 
> *pdev)
>  
>       platform_set_drvdata(pdev, mt);
>  
> -     tzdev = devm_thermal_zone_of_sensor_register(&pdev->dev, 0, mt,
> -                                                  &mtk_thermal_ops);
> -     if (IS_ERR(tzdev)) {
> -             ret = PTR_ERR(tzdev);
> -             goto err_disable_clk_peri_therm;
> +     for (i = 0; i < mt->conf->num_sensors + 1; i++) {
> +             tz = devm_kmalloc(&pdev->dev, sizeof(*tz), GFP_KERNEL);
> +             if (!tz)
> +                     return -ENOMEM;
> +
> +             tz->mt = mt;
> +             tz->id = i;
> +
> +             tzdev = devm_thermal_zone_of_sensor_register(&pdev->dev, i, tz, 
> (i == 0) ?
> +                                                          &mtk_thermal_ops :
> +                                                          
> &mtk_thermal_sensor_ops);
> +
> +             if (IS_ERR(tzdev)) {
> +                     if (PTR_ERR(tzdev) == -ENODEV) {
> +                             dev_warn(&pdev->dev,
> +                                      "sensor %d not registered in thermal 
> zone in dt\n", i);
> +                             continue;
> +                     }
> +                     if (PTR_ERR(tzdev) == -EACCES) {
> +                             ret = PTR_ERR(tzdev);
> +                             goto err_disable_clk_peri_therm;
> +                     }
> +             }
>       }
>  
>       return 0;

Reply via email to