On 23/01/08 23:11 +0100, Willy Tarreau wrote:
> Hi Peter,
> 
> On Wed, Jan 23, 2008 at 01:59:32PM -0800, H. Peter Anvin wrote:
> > Willy Tarreau wrote:
> > >The GEODE MFGPT code assumed that 32kHz was 32000 Hz while the boards
> > >run on a 32.768 kHz digital watch crystal. In practise, it will not
> > >change the timer's frequency as the skew was only 2.4%, but it
> > >should provide more accurate intervals.
> > >- *  Divisor   Hz      Min Delta (S) Max Delta (S)
> > 
> > Seconds are "s", not "S" (S = siemens.)
> 
> You're quite right. Same as we should write kHz and not Khz. But I'm
> used to change other people's work and particularly comments the least
> possible. Do you want an update ?

Please do - I don't mind if you change the comments - better that they
are right.

Jordan

-- 
Jordan Crouse
Systems Software Development Engineer 
Advanced Micro Devices, Inc.


--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to [EMAIL PROTECTED]
More majordomo info at  http://vger.kernel.org/majordomo-info.html
Please read the FAQ at  http://www.tux.org/lkml/

Reply via email to