Commit 92792ac752aa ("virtio-pci: Introduce admin command sending function")
added "__packed" structures to UAPI header linux/virtio_pci.h. This triggers
build failures in the consumer userspace applications without proper 
"definition"
of __packed (e.g., kvmtool build fails).

Moreover, the structures are already packed well, and doesn't need explicit
packing, similar to the rest of the structures in all virtio_* headers. Remove
the __packed attribute.

Fixes: 92792ac752aa ("virtio-pci: Introduce admin command sending function")
Cc: Feng Liu <fe...@nvidia.com>
Cc: Michael S. Tsirkin <m...@redhat.com>
Cc: Yishai Hadas <yish...@nvidia.com>
Cc: Alex Williamson <alex.william...@redhat.com>
Cc: Jean-Philippe Brucker <jean-phili...@linaro.org>
Reviewed-by: Jean-Philippe Brucker <jean-phili...@linaro.org>
Acked-by: Michael S. Tsirkin <m...@redhat.com>
Signed-off-by: Suzuki K Poulose <suzuki.poul...@arm.com>
---
Changes since v1:
  - Fix description for the "Fixes" tag format
  - Collect Tags from Jean-Philippe and Michael
 ---
 include/uapi/linux/virtio_pci.h | 10 +++++-----
 1 file changed, 5 insertions(+), 5 deletions(-)

diff --git a/include/uapi/linux/virtio_pci.h b/include/uapi/linux/virtio_pci.h
index ef3810dee7ef..a8208492e822 100644
--- a/include/uapi/linux/virtio_pci.h
+++ b/include/uapi/linux/virtio_pci.h
@@ -240,7 +240,7 @@ struct virtio_pci_cfg_cap {
 #define VIRTIO_ADMIN_CMD_LEGACY_DEV_CFG_READ           0x5
 #define VIRTIO_ADMIN_CMD_LEGACY_NOTIFY_INFO            0x6
 
-struct __packed virtio_admin_cmd_hdr {
+struct virtio_admin_cmd_hdr {
        __le16 opcode;
        /*
         * 1 - SR-IOV
@@ -252,20 +252,20 @@ struct __packed virtio_admin_cmd_hdr {
        __le64 group_member_id;
 };
 
-struct __packed virtio_admin_cmd_status {
+struct virtio_admin_cmd_status {
        __le16 status;
        __le16 status_qualifier;
        /* Unused, reserved for future extensions. */
        __u8 reserved2[4];
 };
 
-struct __packed virtio_admin_cmd_legacy_wr_data {
+struct virtio_admin_cmd_legacy_wr_data {
        __u8 offset; /* Starting offset of the register(s) to write. */
        __u8 reserved[7];
        __u8 registers[];
 };
 
-struct __packed virtio_admin_cmd_legacy_rd_data {
+struct virtio_admin_cmd_legacy_rd_data {
        __u8 offset; /* Starting offset of the register(s) to read. */
 };
 
@@ -275,7 +275,7 @@ struct __packed virtio_admin_cmd_legacy_rd_data {
 
 #define VIRTIO_ADMIN_CMD_MAX_NOTIFY_INFO 4
 
-struct __packed virtio_admin_cmd_notify_info_data {
+struct virtio_admin_cmd_notify_info_data {
        __u8 flags; /* 0 = end of list, 1 = owner device, 2 = member device */
        __u8 bar; /* BAR of the member or the owner device */
        __u8 padding[6];
-- 
2.34.1


Reply via email to