Hi Bruce,

On Thu, 31 Jan 2008, Bruce Allen wrote:

> > I see similar results on my test systems
> 
> Thanks for this report and for confirming our observations.  Could you 
> please confirm that a single-port bidrectional UDP link runs at wire 
> speed?  This helps to localize the problem to the TCP stack or interaction 
> of the TCP stack with the e1000 driver and hardware.

Yes, a single-port bidirectional UDP test gets full GigE line rate
in both directions with no packet loss.

[EMAIL PROTECTED] ~]$ nuttcp -f-beta -Itx -u -Ru -w2m 192.168.6.79 & nuttcp 
-f-beta -Irx -r -u -Ru -w2m 192.168.6.79
tx:  1187.0078 MB /  10.04 sec =  992.0550 Mbps 19 %TX 7 %RX 0 / 151937 
drop/pkt 0.00 %loss
rx:  1187.1016 MB /  10.03 sec =  992.3408 Mbps 19 %TX 7 %RX 0 / 151949 
drop/pkt 0.00 %loss

                                                -Bill
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to [EMAIL PROTECTED]
More majordomo info at  http://vger.kernel.org/majordomo-info.html
Please read the FAQ at  http://www.tux.org/lkml/

Reply via email to