Previously, the size was only read upon receiving the config interrupt.
This interrupt is sent when the size changes. However, we also need to
read the initial size.
Also make sure to only read the size from config if F_SIZE is enabled.
Fixes: 9778829cffd4 ("virtio: console: Store each console's size in the console
structure")
Signed-off-by: Filip Hejsek <[email protected]>
---
I found this bug while developing patches for QEMU that add virtio
console resize support. If you want to test this, you can get my QEMU
patches from [1]. You will need to disable multiport
using `-device virtio-serial,max_ports=1`.
[1]:
https://lore.kernel.org/all/[email protected]/
As an aside, when I was trying to understand the kernel resizing code,
I noticed two things which didn't make sense to me:
- Why does use_multiport use __virtio_test_bit instead of
virtio_has_feature?
- The VIRTIO_CONSOLE_RESIZE handler sets irq_requested to 1, which I
think makes no sense?
---
drivers/char/virtio_console.c | 52 ++++++++++++++++++++++++++-----------------
1 file changed, 31 insertions(+), 21 deletions(-)
diff --git a/drivers/char/virtio_console.c b/drivers/char/virtio_console.c
index 088182e54deb..c355f6d39274 100644
--- a/drivers/char/virtio_console.c
+++ b/drivers/char/virtio_console.c
@@ -1771,32 +1771,40 @@ static void config_intr(struct virtio_device *vdev)
schedule_work(&portdev->config_work);
}
-static void config_work_handler(struct work_struct *work)
+static void update_size_from_config(struct ports_device *portdev)
{
- struct ports_device *portdev;
+ struct virtio_device *vdev;
+ struct port *port;
+ u16 rows, cols;
- portdev = container_of(work, struct ports_device, config_work);
- if (!use_multiport(portdev)) {
- struct virtio_device *vdev;
- struct port *port;
- u16 rows, cols;
+ vdev = portdev->vdev;
- vdev = portdev->vdev;
- virtio_cread(vdev, struct virtio_console_config, cols, &cols);
- virtio_cread(vdev, struct virtio_console_config, rows, &rows);
+ /*
+ * We'll use this way of resizing only for legacy support.
+ * For multiport devices, use control messages to indicate
+ * console size changes so that it can be done per-port.
+ *
+ * Don't test F_SIZE at all if we're rproc: not a valid feature.
+ */
+ if (is_rproc_serial(vdev) ||
+ use_multiport(portdev) ||
+ !virtio_has_feature(vdev, VIRTIO_CONSOLE_F_SIZE))
+ return;
- port = find_port_by_id(portdev, 0);
- set_console_size(port, rows, cols);
+ virtio_cread(vdev, struct virtio_console_config, cols, &cols);
+ virtio_cread(vdev, struct virtio_console_config, rows, &rows);
- /*
- * We'll use this way of resizing only for legacy
- * support. For newer userspace
- * (VIRTIO_CONSOLE_F_MULTPORT+), use control messages
- * to indicate console size changes so that it can be
- * done per-port.
- */
- resize_console(port);
- }
+ port = find_port_by_id(portdev, 0);
+ set_console_size(port, rows, cols);
+ resize_console(port);
+}
+
+static void config_work_handler(struct work_struct *work)
+{
+ struct ports_device *portdev;
+
+ portdev = container_of(work, struct ports_device, config_work);
+ update_size_from_config(portdev);
}
static int init_vqs(struct ports_device *portdev)
@@ -2054,6 +2062,8 @@ static int virtcons_probe(struct virtio_device *vdev)
__send_control_msg(portdev, VIRTIO_CONSOLE_BAD_ID,
VIRTIO_CONSOLE_DEVICE_READY, 1);
+ update_size_from_config(portdev);
+
return 0;
free_chrdev:
---
base-commit: b927546677c876e26eba308550207c2ddf812a43
change-id: 20251224-virtio-console-fix-3d46980ef569
Best regards,
--
Filip Hejsek <[email protected]>