It's understood that the AB8500 should be subordinate to the DB8500; however, the AB8500 uses the GIC as it's interrupt controller. If we do not specify which IRQ controller to use the default is to use the next encountered IRQ controller as we climb the tree. This would be the DB8500. This patch ensures the AB8500 makes use of the correct interrupt controller.
Acked-by: Linus Walleij <[email protected]> Signed-off-by: Lee Jones <[email protected]> --- arch/arm/boot/dts/dbx5x0.dtsi | 1 + 1 file changed, 1 insertion(+) diff --git a/arch/arm/boot/dts/dbx5x0.dtsi b/arch/arm/boot/dts/dbx5x0.dtsi index 04cd525..daedefe 100644 --- a/arch/arm/boot/dts/dbx5x0.dtsi +++ b/arch/arm/boot/dts/dbx5x0.dtsi @@ -332,6 +332,7 @@ ab8500@5 { compatible = "stericsson,ab8500"; reg = <5>; /* mailbox 5 is i2c */ + interrupt-parent = <&intc>; interrupts = <0 40 0x4>; interrupt-controller; #interrupt-cells = <2>; -- 1.7.9.5 -- To unsubscribe from this list: send the line "unsubscribe linux-kernel" in the body of a message to [email protected] More majordomo info at http://vger.kernel.org/majordomo-info.html Please read the FAQ at http://www.tux.org/lkml/

