On 09/21/2012 02:10 PM, Anton Vorontsov wrote:

> On Tue, Aug 21, 2012 at 05:06:52PM +0900, Chanwoo Choi wrote:
>> This patch check periodically fully charged state of battery to protect
>> overcharge and overheat. If battery is fully charged, stop charging
>> and check droped voltage with 'fullbatt_vchkdrop_ms' period. When voltage
>> of battery is more droped than 'fullbatt_vchkdrop_uV' voltage,
>> charger-manager will restart charging for battery.
>>
>> Signed-off-by: Chanwoo Choi <cw00.c...@samsung.com>
>> Signed-off-by: Myungjoo Ham <myungjoo....@samsung.com>
>> Signed-off-by: Kyungmin Park <kyungmin.p...@samsung.com>
>> ---
> 
> Applied, thank you.
> 
> There were some minor issues, but I fixed them up:
> 
> [...]
>> +    } else if (!cm->emergency_stop
>> +                    && is_ext_pwr_online(cm) && !cm->charger_enabled) {
> 
> Wrong && placement (should have been on the previous line).
> 
>> +            fullbatt_vchk(&cm->fullbatt_vchk_work.work);
>> +
>> +    /*
>> +     * Check whether fully charged state to protect overcharge
>> +     * if charger-manager is charging for battery.
>> +     */
>> +    } else if (!cm->emergency_stop
>> +                    && is_full_charged(cm) && cm->charger_enabled) {
> 
> Ditto.
> 


Thanks for your reply and applied it.

I will consider your comment about coding style.

Best Regards,
Chanwoo Choi
--