Am 09.12.2012 13:55, schrieb Lars-Peter Clausen:
On 12/09/2012 01:21 PM, Alexander Holler wrote:
This driver makes the time from HID sensors (hubs) which are offering
such available like any other RTC does.

Currently the time can only be read. Setting the time must be done
through sending a report, which currently isn't supported by
hid-sensor-hub.

It is necessary that all values like year, month etc, are send as
8bit values (1 byte each) and all of them in 1 report. Also the
spec HUTRR39b doesn't define the range of the year field, we
tread it as 0 - 99 because that's what most RTCs I know about are
offering.

I don't think we should register a IIO device for this. Just an RTC device
should be fully sufficient.


You would have to implement all the used services hid-sensor-hub offers in the rtc-driver again.

Regards,

Alexander

--