The Linux Power Supply framework expects battery temperatures to have
a resolution of 0.1 degree Celsius; however, the AB8500 btemp driver
supplies a battery temperature resolution of 1 degree Celsius. We
therefore have to use a factor 10 on the measured values.

Signed-off-by: Lee Jones <lee.jo...@linaro.org>
---
 drivers/power/ab8500_btemp.c |   12 ++++++------
 1 file changed, 6 insertions(+), 6 deletions(-)

diff --git a/drivers/power/ab8500_btemp.c b/drivers/power/ab8500_btemp.c
index efeb6dd..3ad47b0 100644
--- a/drivers/power/ab8500_btemp.c
+++ b/drivers/power/ab8500_btemp.c
@@ -746,22 +746,22 @@ static int ab8500_btemp_get_temp(struct ab8500_btemp *di)
        } else {
                if (di->events.btemp_low) {
                        if (temp > di->btemp_ranges.btemp_low_limit)
-                               temp = di->btemp_ranges.btemp_low_limit;
+                               temp = di->btemp_ranges.btemp_low_limit * 10;
                        else
                                temp = di->bat_temp * 10;
                } else if (di->events.btemp_high) {
                        if (temp < di->btemp_ranges.btemp_high_limit)
-                               temp = di->btemp_ranges.btemp_high_limit;
+                               temp = di->btemp_ranges.btemp_high_limit * 10;
                        else
                                temp = di->bat_temp * 10;
                } else if (di->events.btemp_lowmed) {
                        if (temp > di->btemp_ranges.btemp_med_limit)
-                               temp = di->btemp_ranges.btemp_med_limit;
+                               temp = di->btemp_ranges.btemp_med_limit * 10;
                        else
                                temp = di->bat_temp * 10;
                } else if (di->events.btemp_medhigh) {
                        if (temp < di->btemp_ranges.btemp_med_limit)
-                               temp = di->btemp_ranges.btemp_med_limit;
+                               temp = di->btemp_ranges.btemp_med_limit * 10;
                        else
                                temp = di->bat_temp * 10;
                } else
@@ -1030,8 +1030,8 @@ static int __devinit ab8500_btemp_probe(struct 
platform_device *pdev)
                ab8500_btemp_periodic_work);
 
        /* Set BTEMP thermal limits. Low and Med are fixed */
-       di->btemp_ranges.btemp_low_limit = BTEMP_THERMAL_LOW_LIMIT;
-       di->btemp_ranges.btemp_med_limit = BTEMP_THERMAL_MED_LIMIT;
+       di->btemp_ranges.btemp_low_limit = BTEMP_THERMAL_LOW_LIMIT * 10;
+       di->btemp_ranges.btemp_med_limit = BTEMP_THERMAL_MED_LIMIT * 10;
 
        ret = abx500_get_register_interruptible(di->dev, AB8500_CHARGER,
                AB8500_BTEMP_HIGH_TH, &val);
-- 
1.7.9.5

--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majord...@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html
Please read the FAQ at  http://www.tux.org/lkml/

Reply via email to