On Sat, Apr 14, 2001 at 03:27:53PM +0100, Alan Cox wrote:
> > For example the Zyxel 681 SDSL-Router breaks ECN by
> > stripping 0x80 (ECN Cwnd Reduced) but not 0x40 (ECN Echo)
> > (TOS bits) on all SYN packets (!).
> > 
> > I complained because of this two times more than a month ago
> > but they do not even respond.
> 
> If the router claims to be RFC compliant then you may want to investigate
> trading standards bodies. In the UK at least things like the advertising 
> standards agency get upset by people who claim standards compliance, are shown
> not to be compliant and are not fixing things..

FYI: I just tested a beta firmare that does not break ECN.
(ZyXEL firmware v2.50(T.05)b6 | 03/28/2001)

I hope that Zyxel will make a release soon, the last official firmare
does not support it. (Ahm, people that are willing to upgrade should
do it on _both_ sides)

-- 

  ciao - 
    Stefan
-
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to [EMAIL PROTECTED]
More majordomo info at  http://vger.kernel.org/majordomo-info.html
Please read the FAQ at  http://www.tux.org/lkml/

Reply via email to