Current equation on the comment is wrong.
For linear mapping starting from 0, the equation is (maxV-minV)/stepV + 1.
Since the linear mapping for PALMAS is not all starting from 0, the equation
on the comment is not useful and misleading. Thus remove it.

Signed-off-by: Axel Lin <axel....@ingics.com>
---
 drivers/regulator/palmas-regulator.c | 6 ------
 1 file changed, 6 deletions(-)

diff --git a/drivers/regulator/palmas-regulator.c 
b/drivers/regulator/palmas-regulator.c
index fba4faa..7e2b165 100644
--- a/drivers/regulator/palmas-regulator.c
+++ b/drivers/regulator/palmas-regulator.c
@@ -201,12 +201,6 @@ static unsigned int palmas_smps_ramp_delay[4] = {0, 10000, 
5000, 2500};
 #define SMPS_CTRL_MODE_ECO             0x02
 #define SMPS_CTRL_MODE_PWM             0x03
 
-/* These values are derived from the data sheet. And are the number of steps
- * where there is a voltage change, the ranges at beginning and end of register
- * max/min values where there are no change are ommitted.
- *
- * So they are basically (maxV-minV)/stepV
- */
 #define PALMAS_SMPS_NUM_VOLTAGES       122
 #define PALMAS_SMPS10_NUM_VOLTAGES     2
 #define PALMAS_LDO_NUM_VOLTAGES                50
-- 
1.8.1.2



--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majord...@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html