Current equation on the comment is wrong. For linear mapping starting from 0, the equation is (maxV-minV)/stepV + 1. Since the linear mapping for PALMAS is not all starting from 0, the equation on the comment is not useful and misleading. Thus remove it.
Signed-off-by: Axel Lin <axel....@ingics.com> --- drivers/regulator/palmas-regulator.c | 6 ------ 1 file changed, 6 deletions(-) diff --git a/drivers/regulator/palmas-regulator.c b/drivers/regulator/palmas-regulator.c index fba4faa..7e2b165 100644 --- a/drivers/regulator/palmas-regulator.c +++ b/drivers/regulator/palmas-regulator.c @@ -201,12 +201,6 @@ static unsigned int palmas_smps_ramp_delay[4] = {0, 10000, 5000, 2500}; #define SMPS_CTRL_MODE_ECO 0x02 #define SMPS_CTRL_MODE_PWM 0x03 -/* These values are derived from the data sheet. And are the number of steps - * where there is a voltage change, the ranges at beginning and end of register - * max/min values where there are no change are ommitted. - * - * So they are basically (maxV-minV)/stepV - */ #define PALMAS_SMPS_NUM_VOLTAGES 122 #define PALMAS_SMPS10_NUM_VOLTAGES 2 #define PALMAS_LDO_NUM_VOLTAGES 50 -- 1.8.1.2 -- To unsubscribe from this list: send the line "unsubscribe linux-kernel" in the body of a message to majord...@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html Please read the FAQ at http://www.tux.org/lkml/