On Thu, Mar 13, 2014 at 07:43:01PM +0800, Daniel J Blueman wrote: > For systems with multiple servers and routed fabric, all northbridges get > assigned to the first server. Fix this by also using the node reported from > the PCI bus. For single-fabric systems, the northbriges are on PCI bus 0 > by definition, which are on NUMA node 0 by definition, so this is invarient > on most systems.
Yeah, I think this is of very low risk for !Numascale setups. :-) So Acked-by: Borislav Petkov <b...@suse.de> > Tested on fam10h and fam15h single and multi-fabric systems and candidate > for stable. I'm not sure about it - this is only reporting the wrong node, right? Does anything depend on that node setting being correct and breaks due to this? Thanks. -- Regards/Gruss, Boris. Sent from a fat crate under my desk. Formatting is fine. -- -- To unsubscribe from this list: send the line "unsubscribe linux-kernel" in the body of a message to majord...@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html Please read the FAQ at http://www.tux.org/lkml/