From: Matthias Brugger <matthias....@gmail.com>

The calculation of value quot for highspeed register set to three
was wrong. This patch fixes the calculation so that the serial port
for baudrates bigger then 576000 baud is working correctly.

Signed-off-by: Matthias Brugger <matthias....@gmail.com>
---
 drivers/tty/serial/8250/8250_mtk.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/tty/serial/8250/8250_mtk.c 
b/drivers/tty/serial/8250/8250_mtk.c
index 8f37d57..de7aae5 100644
--- a/drivers/tty/serial/8250/8250_mtk.c
+++ b/drivers/tty/serial/8250/8250_mtk.c
@@ -81,7 +81,7 @@ mtk8250_set_termios(struct uart_port *port, struct ktermios 
*termios,
                /* Set to highest baudrate supported */
                if (baud >= 1152000)
                        baud = 921600;
-               quot = DIV_ROUND_CLOSEST(port->uartclk, 256 * baud);
+               quot = (port->uartclk / (256 * baud)) + 1;
        }
 
        /*
-- 
1.9.1

--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majord...@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html
Please read the FAQ at  http://www.tux.org/lkml/