Hi,

On Mon, Nov 03, 2014 at 10:26:43AM +0900, Hugh Kang wrote:
> From: "hugh.kang" <[email protected]>
> 
> If a regulator is set by always-on option, the regulator will be set forever.
> For example, suppose LDO1 is set to always-on at RevA.dts with including of 
> a.dtsi. After that
> RevB.dts may wants to include the same a.dtsi but override the LDO1 always-on 
> option. However,
> currently there is no way to delete the always-on option, even when we change 
> the LDO1 option value,
> the always-on setting is still remains.

Why don't you split your devicetrees according to the real hardware and
set the always-on property only for revA?

Regards,

Markus

> 
> Signed-off-by: hugh.kang <[email protected]>
> ---
>  drivers/regulator/of_regulator.c | 6 ++++++
>  1 file changed, 6 insertions(+)
> 
> diff --git a/drivers/regulator/of_regulator.c 
> b/drivers/regulator/of_regulator.c
> index ee5e67b..4178dbd 100644
> --- a/drivers/regulator/of_regulator.c
> +++ b/drivers/regulator/of_regulator.c
> @@ -52,7 +52,13 @@ static void of_get_regulation_constraints(struct 
> device_node *np,
>               constraints->valid_ops_mask |= REGULATOR_CHANGE_CURRENT;
>  
>       constraints->boot_on = of_property_read_bool(np, "regulator-boot-on");
> +     if (of_property_read_bool(np, "regulator-disable-boot-on"))
> +             constraints->boot_on = false;
> +
>       constraints->always_on = of_property_read_bool(np, 
> "regulator-always-on");
> +     if (of_property_read_bool(np, "regulator-disable-always-on"))
> +             constraints->always_on = false;
> +
>       if (!constraints->always_on) /* status change should be possible. */
>               constraints->valid_ops_mask |= REGULATOR_CHANGE_STATUS;
>  
> -- 
> 1.8.3.2
> 
> --
> To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
> the body of a message to [email protected]
> More majordomo info at  http://vger.kernel.org/majordomo-info.html
> Please read the FAQ at  http://www.tux.org/lkml/
> 

-- 
Pengutronix e.K.                           |                             |
Industrial Linux Solutions                 | http://www.pengutronix.de/  |
Peiner Str. 6-8, 31137 Hildesheim, Germany | Phone: +49-5121-206917-0    |
Amtsgericht Hildesheim, HRA 2686           | Fax:   +49-5121-206917-5555 |

Attachment: signature.asc
Description: Digital signature

Reply via email to