Hi,

On Wed, Jan 07, 2015 at 01:26:55PM -0800, Todd E Brandt wrote:
> X-Power AXP288 PMIC Fuel Gauge Driver
> 
>  new power_supply driver at driver/power
>  interfaces with the axp20x mfd driver as a cell
>  provides battery info and monitors for changes
>  generates alerts on temperature and capacity issues
> 
> [...]
>
> +static int fuel_gauge_battery_health(struct axp288_fg_info *info)
> +{
> +     int temp, vocv;
> +     int ret, health = POWER_SUPPLY_HEALTH_UNKNOWN;
> +
> +     ret = fuel_gauge_get_btemp(info, &temp);
> +     if (ret < 0)
> +             goto health_read_fail;
> +
> +     ret = fuel_gauge_get_vocv(info, &vocv);
> +     if (ret < 0)
> +             goto health_read_fail;
> +
> +     if (vocv > info->pdata->max_volt)
> +             health = POWER_SUPPLY_HEALTH_OVERVOLTAGE;
> +     else if (temp > info->pdata->max_temp ||
> +                     temp < info->pdata->min_temp)
> +             health = POWER_SUPPLY_HEALTH_OVERHEAT;

if (temp < info->pdata->min_temp)
    health = POWER_SUPPLY_HEALTH_COLD;

> +     else if (vocv < info->pdata->min_volt)
> +             health = POWER_SUPPLY_HEALTH_DEAD;
> +     else
> +             health = POWER_SUPPLY_HEALTH_GOOD;
> +
> +health_read_fail:
> +     return health;
> +}
>
> [...]
>
> +static int axp288_fuel_gauge_remove(struct platform_device *pdev)
> +{
> +     return 0;
> +}

You can drop this function if nothing needs to be cleaned, but
that's not the case, so where is the cleanup code?

> [...]

-- Sebastian