Datasheet says (Page 2) that typical value for sensitivity
for 16 bits mode on Z-axis is 770. Anyhow, looking at the
input driver provided by Memsic the value for MMC35240 is
1024.
Also, testing shows that using 1024 for Z-axis senzitivity
offers better results.
Fixes: abeb6b1e7b ("iio: magnetometer: Add support for MEMSIC MMC35240")
Signed-off-by: Daniel Baluta <[email protected]>
---
drivers/iio/magnetometer/mmc35240.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/iio/magnetometer/mmc35240.c
b/drivers/iio/magnetometer/mmc35240.c
index 35eb6fd..88be660 100644
--- a/drivers/iio/magnetometer/mmc35240.c
+++ b/drivers/iio/magnetometer/mmc35240.c
@@ -77,7 +77,7 @@ static const struct {
} mmc35240_props_table[] = {
/* 16 bits, 100Hz ODR */
{
- {1024, 1024, 770},
+ {1024, 1024, 1024},
32768,
},
/* 16 bits, 200Hz ODR */
--
1.9.1
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/