Datasheet says (Page 2) that typical value for sensitivity
for 16 bits mode on Z-axis is 770. Anyhow, looking at the
input driver provided by Memsic the value for MMC35240 is
1024.

Also, testing shows that using 1024 for Z-axis senzitivity
offers better results.

Fixes: abeb6b1e7b ("iio: magnetometer: Add support for MEMSIC MMC35240")
Signed-off-by: Daniel Baluta <daniel.bal...@intel.com>
---
 drivers/iio/magnetometer/mmc35240.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/iio/magnetometer/mmc35240.c 
b/drivers/iio/magnetometer/mmc35240.c
index 7bc72b3..73fa111 100644
--- a/drivers/iio/magnetometer/mmc35240.c
+++ b/drivers/iio/magnetometer/mmc35240.c
@@ -77,7 +77,7 @@ static const struct {
 } mmc35240_props_table[] = {
        /* 16 bits, 100Hz ODR */
        {
-               {1024, 1024, 770},
+               {1024, 1024, 1024},
                32768,
        },
        /* 16 bits, 200Hz ODR */
-- 
1.9.1

--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majord...@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html