On Tuesday 14 July 2015 02:34:13 Krzysztof Kozlowski wrote: > The driver during probe registers a power supply notifier > (with bq2415x_notifier_call() callback) and calls it manually right > after. The notifier callback function schedules driver's workqueue > (bq->work). > > However the workqueue was initialized after these two events (after > registering power supply notifier and calling manually the callback). > > When power supply core notified the driver (executing its > bq2415x_notifier_call() callback) the scheduled workqueue could be > still uninitialized. > > Signed-off-by: Krzysztof Kozlowski <[email protected]> > Reported-by: Pali Rohár <[email protected]> > > --- > > I don't have the hardware, please test. Additionally I could not find > the commit which introduced the issue so I did not cc-stable. > --- > drivers/power/bq2415x_charger.c | 2 +- > 1 file changed, 1 insertion(+), 1 deletion(-) > > diff --git a/drivers/power/bq2415x_charger.c > b/drivers/power/bq2415x_charger.c index e98dcb661cc9..527ed0f18796 > 100644 > --- a/drivers/power/bq2415x_charger.c > +++ b/drivers/power/bq2415x_charger.c > @@ -1601,6 +1601,7 @@ static int bq2415x_probe(struct i2c_client > *client, bq->reported_mode = BQ2415X_MODE_OFF; > bq->autotimer = 0; > bq->automode = 0; > + INIT_DELAYED_WORK(&bq->work, bq2415x_timer_work); > > if (np || ACPI_HANDLE(bq->dev)) { > ret = device_property_read_u32(bq->dev, > @@ -1677,7 +1678,6 @@ static int bq2415x_probe(struct i2c_client > *client, dev_info(bq->dev, "automode not supported\n"); > } > > - INIT_DELAYED_WORK(&bq->work, bq2415x_timer_work); > bq2415x_set_autotimer(bq, 1); > > dev_info(bq->dev, "driver registered\n");
Looks like this is really problem. I sent alternative patch to mailing list which should fix this problem too plus allows to load bq2415x_charger.ko in n900 qemu. -- Pali Rohár [email protected]
signature.asc
Description: This is a digitally signed message part.