Hello.

On 08/04/2015 03:28 PM, Geert Uytterhoeven wrote:

Currently the CPG/MSTP Clock Domain code looks for MSTP clocks to power
manage a device.

Unfortunately, on R-Mobile APE6 (r8a73a4) and SH-Mobile AG5 (sh73a0),
the Bus State Controller (BSC) is not power-managed by an MSTP clock,
but by a plain CPG clock (zb_clk).  Add a special case to handle this,
so the clock is properly managed, and devices connected to the BSC work
as expected.

Signed-off-by: Geert Uytterhoeven <geert+rene...@glider.be>
Reviewed-by: Ulf Hansson <ulf.hans...@linaro.org>
[...]

diff --git a/drivers/clk/shmobile/clk-mstp.c b/drivers/clk/shmobile/clk-mstp.c
index b1df7b2f1e970adb..a117c3f0f257b5e1 100644
--- a/drivers/clk/shmobile/clk-mstp.c
+++ b/drivers/clk/shmobile/clk-mstp.c
@@ -259,6 +259,10 @@ int cpg_mstp_attach_dev(struct generic_pm_domain *domain, 
struct device *dev)
                                            "renesas,cpg-mstp-clocks"))
                        goto found;

+               /* BSC on r8a73a4/sh73a0 uses zb_clk instead of an mstp clock*/

   Please add a space before */.

+               if (!strcmp(clkspec.np->name, "zb_clk"))
+                       goto found;
+
                of_node_put(clkspec.np);
                i++;
        }

MBR, Sergei


--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majord...@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html
Please read the FAQ at  http://www.tux.org/lkml/

Reply via email to