On Tue, Aug 04, 2015 at 08:50:41PM +0530, Kishon Vijay Abraham I wrote:
> No functional change. Previously omap_control_phy_power() was used to power

there is a slight functional change. You moved PHY power off from before
to after pm_runtime_enable(), clk_prepare_enable() and creation of the
PHY device. That ought to have a slight impact on how the driver
behaves.

-- 
balbi