Hi! > >> But regulators already have "regulator-max-microamp" property. So what > >> about: > >> > >> max-microamp : maximum intensity in microamperes of the LED > >> (torch LED for flash devices) > >> max-flash-microamp : initial intensity in microamperes of the > >> flash LED; it is required to enable support > >> for the flash led > >> flash-timeout-microseconds : timeout in microseconds after which flash > >> led is turned off > >> > >> If you had indicator on the same led, I guess > >> > >> indicator-microamp : recommended intensity in microamperes of the LED > >> for indication > > The value for the indicator is maximum as well, not just a > recommendation.
Actually, no. This is all for one LED, if you want to use it as a flash, torch and indicator. You already know the maximum value with max-microamp. Best regards, Pavel -- (english) http://www.livejournal.com/~pavelmachek (cesky, pictures) http://atrey.karlin.mff.cuni.cz/~pavel/picture/horses/blog.html -- To unsubscribe from this list: send the line "unsubscribe linux-media" in the body of a message to majord...@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html