Hi!

> >> But regulators already have "regulator-max-microamp" property. So what
> >> about:
> >>
> >> max-microamp :     maximum intensity in microamperes of the LED
> >>                 (torch LED for flash devices)
> >> max-flash-microamp :     initial intensity in microamperes of the
> >>               flash LED; it is required to enable support
> >>               for the flash led
> >> flash-timeout-microseconds : timeout in microseconds after which flash
> >>               led is turned off
> >>
> >> If you had indicator on the same led, I guess
> >>
> >> indicator-microamp : recommended intensity in microamperes of the LED
> >>                  for indication
> 
> The value for the indicator is maximum as well, not just a
> recommendation.

Actually, no.

This is all for one LED, if you want to use it as a flash, torch and
indicator. You already know the maximum value with max-microamp.

Best regards,
                                                                        Pavel
-- 
(english) http://www.livejournal.com/~pavelmachek
(cesky, pictures) 
http://atrey.karlin.mff.cuni.cz/~pavel/picture/horses/blog.html
--
To unsubscribe from this list: send the line "unsubscribe linux-media" in
the body of a message to majord...@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html

Reply via email to