On 03/16/2015 11:44 PM, Antti Palosaari wrote:
On 03/16/2015 11:47 PM, Antti Palosaari wrote:
On 03/16/2015 12:57 AM, Benjamin Larsson wrote:
Signed-off-by: Benjamin Larsson <benja...@southpole.se>
Applied.
I found this does not work at least for DVB-C. After playing with
modulator I find reg 0x85 on bank 1 is likely AGC. Its value is changed
according to RF level even modulation itself is turned off.
I will likely remove that patch... It is a bit hard to find out lock
bits and it comes even harder without a modulator. Using typical tricks
to plug and unplug antenna, while dumping register values out is error
prone as you could not adjust signal strength nor change modulation
parameters causing wrong decision easily.
regards
Antti
Indeed the logic was inverted. Will respin the patch.
MvH
Benjamin Larsson
--
To unsubscribe from this list: send the line "unsubscribe linux-media" in
the body of a message to majord...@vger.kernel.org
More majordomo info at http://vger.kernel.org/majordomo-info.html