Hi Laurent

> > >>  - s2d2 (for 200MHz)
> > >>  - s2d1 (for 400MHz)
> > > 
> > > Thank you for the information. Do you mean that different FCP instances
> > > use different clocks ? If so, could you tell us which clock is used by
> > > each instance in th H3 ES1 ?
> > 
> > Sorry for my confusable mail.
> > All FCP on H3 ES1 is using above,
> > but, M3 or E3 will use different clock.
> > 
> > Is this more clear ?
> 
> Does it mean that every FCP instance uses both the S2D2 and the S2D1 clocks 
> as 
> functional clocks on H3 ES1 ?

 - s2d2 (200MHz) is for APB-IF,
 - s2d1 (400MHz) is for AXI-IF, and internal

Is this clear answer ?


--
To unsubscribe from this list: send the line "unsubscribe linux-media" in
the body of a message to majord...@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html