On Thu, 14 Jan 1999, Y2K wrote:

> Hi all
> During boot time system is showing following lines
> eth0:NE1000 found at 0x6100,using IRQ10
> eth0:timeout waiting for Tx RDC
> 
> and after this the m/c is not in network.Cable is not faulty.
> Can any one tell me what is Tx RDC error.

I remember that one from last time I had to beat a pc into submission
before it worked, though I can't remember at which stage it came.

It was either the missed interrupt due to int 10 being reserved for the
pci bus, or the timeouts because the card was set to autodetect the
connector and stupidly picked the BNC instead of RJ-45 connector, since I
can't remember which was the cause I'll give both as possibilities.

Make sure int 10 is marked as ISA/LEGACY, non pci/pnp in your bios setup
and make sure the card uses the right connector.

HTH
-- 
Henrik Olsen,  Dawn Solutions I/S
URL=http://www.iaeste.dk/~henrik/
  Plug'n'play works wonders in the environment it was designed for 
    ie. any periferal can be set to anything.
  This is NOT a description of any existing hardware.
  Draw your own conclusions from this.                Henrik Olsen

-
To unsubscribe from this list: send the line "unsubscribe linux-net" in
the body of a message to [EMAIL PROTECTED]

Reply via email to