On 19/11/14 17:10, Dr. H. Nikolaus Schaller wrote:

>> You don't need to ask. The connector calls invert_vid_out_polarity
>> before enabling the output.
> 
> Unfortunately it doesn’t. At least not always.
> 
> It does only for pdata systems but not for DT based systems:
> 
>       if (!ddata->dev->of_node) {
>               in->ops.atv->set_type(in, ddata->connector_type);
>               in->ops.atv->invert_vid_out_polarity(in,
>                       ddata->invert_polarity);
>       }
> 
> Not calling is in our case different from calling with ddata->invert_polarity 
> == 0.

Ah, sorry, my mistake. I should've read the code more carefully =).

So, with DT only approach, those calls above are not supported. If you
make the OPA driver DT only, you can remove those functions.

You only need to set the invert-polarity property in the venc DT node.

 Tomi


Attachment: signature.asc
Description: OpenPGP digital signature

Reply via email to