Hi Sascha,

> The thermal code uses int, long and unsigned long for temperatures
> in different places.
> 
> Using an unsigned type limits the thermal framework to positive
> temperatures without need. Also several drivers currently will report
> temperatures near UINT_MAX for temperatures below 0°C. This will
> probably immediately shut the machine down due to overtemperature if
> started below 0°C.
> 
> 'long' is 64bit on several architectures. This is not needed since
> INT_MAX °mC is above the melting point of all known materials.
> 
> Consistently use a plain 'int' for temperatures throughout the
> thermal code and the drivers. This only changes the places in the
> drivers where the temperature is passed around as pointer, when
> drivers internally use another type this is not changed.
> 
> Signed-off-by: Sascha Hauer <s.ha...@pengutronix.de>

Sascha, thanks for this cleanup work. 

Reviewed-by: Lukasz Majewski <l.majew...@samsung.com>

-- 
Best regards,

Lukasz Majewski