Fixed by downgrading to OM 6.1 (thanks to Ryan Miller for pointing out
his fix).
- Ryan
Ryan Pugatch wrote:
> Has anyone run in to this before?
>
> [r...@sentinel ~]# racadm setniccfg -s 10.10.6.25 255.255.0.0 10.10.6.1
> ERROR: Unable to perform requested operation.
> If the operation attempted was to configure DRAC, possible reason may be
> that
> Local Configuration using RACADM is disabled.
> ===============================================================================
>
>
> IMPORTANT NOTE!
> The RAC is unable to communicate with the BMC. This condition may
> occur because of (1) no BMC is present, (2) missing or disfunctional
> IPMI-related software components. Many RAC features depend on BMC
> connectivity in order to work properly, and you may see failures
> as a result.
> ===============================================================================
>
>
>
>
> Also, most things to query the hardware via omreport fail - ie:
>
> [r...@sentinel ~]# omreport chassis memory
> Memory Information
>
> Error : Memory object not found
>
>
> It's a brand new R610.
>
> I haven't run in to this before. Is there something obvious missing?
>
> Thanks
>
> Ryan
_______________________________________________
Linux-PowerEdge mailing list
[email protected]
https://lists.us.dell.com/mailman/listinfo/linux-poweredge
Please read the FAQ at http://lists.us.dell.com/faq