Fixed by downgrading to OM 6.1 (thanks to Ryan Miller for pointing out 
his fix).

        - Ryan


Ryan Pugatch wrote:
> Has anyone run in to this before?
> 
> [r...@sentinel ~]# racadm setniccfg -s 10.10.6.25 255.255.0.0 10.10.6.1
> ERROR: Unable to perform requested operation.
> If the operation attempted was to configure DRAC, possible reason may be 
> that
> Local Configuration using RACADM is disabled.
> ===============================================================================
>  
> 
> IMPORTANT NOTE!
> The RAC is unable to communicate with the BMC. This condition may
> occur because of (1) no BMC is present, (2) missing or disfunctional
> IPMI-related software components. Many RAC features depend on BMC
> connectivity in order to work properly, and you may see failures
> as a result.
> ===============================================================================
>  
> 
> 
> 
> Also, most things to query the hardware via omreport fail - ie:
> 
> [r...@sentinel ~]# omreport chassis memory
> Memory Information
> 
> Error : Memory object not found
> 
> 
> It's a brand new R610.
> 
> I haven't run in to this before.  Is there something obvious missing?
> 
> Thanks
> 
> Ryan

_______________________________________________
Linux-PowerEdge mailing list
[email protected]
https://lists.us.dell.com/mailman/listinfo/linux-poweredge
Please read the FAQ at http://lists.us.dell.com/faq

Reply via email to