Prasanth, That worked great! Apparently recently we've been doing a granular install, as we almost never fire up this web GUI. So this worked for me.
yum -y install srvadmin-tomcat systemctl start dsm_om_connsvc then connect to https://<server<https://%3cserver> IP>:1311 Well, it sort of worked - this web GUI is still not AD-integrated; had to log in as root (grumble, grumble). Our DRAC is AD-integrated. Still, for no more often than we use this web GUI this is OK. Spike ---------------------------------------------------------------------- Message: 1 Date: Thu, 17 Dec 2015 08:15:33 +0530 From: Subject: Re: [Linux-PowerEdge] RHEL 7.0/OMSA 8.2 -- what service listens To: Message-ID: Content-Type: text/plain; charset="us-ascii" Dell - Internal Use - Confidential Spike, You are correct, dsm_om_connsvc is the one which listens on port 1311 as shown below: ################################################################### netstat -plan | grep 1311 tcp6 0 0 :::1311 :::* LISTEN 7363/dsm_om_connsvc ################################################################### Make sure that you have checked the component "Server Administrator Web Server Interface" while installing OMSA as it supports granular installation. FYI this service is provided by srvadmin-tomcat rpm. You can check by running rpm -qa | grep srvadmin-tomcat. Hope it helps. Regards, Prasanth K S R -----Original Message-----
_______________________________________________ Linux-PowerEdge mailing list Linux-PowerEdge@dell.com https://lists.us.dell.com/mailman/listinfo/linux-poweredge