On 05/10/2018 12:37 PM, Stephen John Smoogen wrote:
On 10 May 2018 at 09:57, Patrick Boutilier <[email protected]> wrote:On 05/10/2018 10:34 AM, lejeczek wrote:On 09/05/18 22:34, R S wrote:Is there a mechanism that prevents me to downgrade from v6.5.0 back to v6.4.0 on a R710/T710? I downgraded the iDRAC from 2.90 to v2.80 and the 'Connection Failed' issue is still there, so I'm trying to downgrade the BIOS.I've just downgraded back to 3.2.2 on one r815 and it seems that it actually might be iDrac6 =! new Java. I wonder if users of newer iDracs also experience this problem?Newer iDRACs can use html5 instead of java plugin for the console. Not sure if it is the default but it is possible to change from Java to html5.I think that is only on the iDrac8 and some? iDrac7 so on an iDrac6 probably will not have it.
Definitely no html5 with iDrac6. Only on newer iDracs. We found that the newest java puts in a
security fix to remove accepting weak encryption. the 'fix' was to edit /usr/lib/jvm/java-openjdk/jre/lib/security/java.security and comment out the "jdk.jar.disabledAlgorithms=" line. Not great.. but it got the newer javas to talk to the old consoles. I would also uncomment the line afterwords.
<<attachment: boutilpj.vcf>>