Additional file descriptor for SMP MADs should be closed before running
ibnd_discover_fabric() to avoid parallel usage of two SMP file descriptors

Signed-off-by: Vladimir Koushnir <vladim...@mellanox.com>
Signed-off-by: Hal Rosenstock <h...@mellanox.com>
---
Change since v2:
Only SMP query for NodeInfo if (!all && dr_path) - same as current code

Change since v1:
Per Ira's comment, moved location of SMP query for NodeInfo
so partial fabric DR query will work.

diff --git a/src/iblinkinfo.c b/src/iblinkinfo.c
index 92ff3c6..5f2b677 100644
--- a/src/iblinkinfo.c
+++ b/src/iblinkinfo.c
@@ -594,6 +594,7 @@ int main(int argc, char **argv)
        ibnd_fabric_t *diff_fabric = NULL;
        struct ibmad_port *ibmad_port;
        ib_portid_t port_id = { 0 };
+       uint8_t ni[IB_SMP_DATA_SIZE] = { 0 };
        int mgmt_classes[3] =
            { IB_SMI_CLASS, IB_SMI_DIRECT_CLASS, IB_SA_CLASS };
 
@@ -659,6 +660,7 @@ int main(int argc, char **argv)
        node_name_map = open_node_name_map(node_name_map_file);
 
        if (dr_path && load_cache_file) {
+               mad_rpc_close_port(ibmad_port);
                fprintf(stderr, "Cannot specify cache and direct route path\n");
                exit(1);
        }
@@ -679,6 +681,16 @@ int main(int argc, char **argv)
                               guid_str);
        }
 
+       if (!all && dr_path) {
+               if (!smp_query_via(ni, &port_id, IB_ATTR_NODE_INFO, 0,
+                                  ibd_timeout, ibmad_port)){
+                       mad_rpc_close_port(ibmad_port);
+                       fprintf(stderr, "Failed to get local Node Info\n");
+                       exit(1);
+               }
+       }
+       mad_rpc_close_port(ibmad_port);
+
        if (diff_cache_file &&
            !(diff_fabric = ibnd_load_fabric(diff_cache_file, 0)))
                IBEXIT("loading cached fabric for diff failed\n");
@@ -723,11 +735,6 @@ int main(int argc, char **argv)
                        fprintf(stderr, "Failed to find port: %s\n", guid_str);
        } else if (!all && dr_path) {
                ibnd_port_t *p = NULL;
-               uint8_t ni[IB_SMP_DATA_SIZE] = { 0 };
-
-               if (!smp_query_via(ni, &port_id, IB_ATTR_NODE_INFO, 0,
-                                  ibd_timeout, ibmad_port))
-                       return -1;
                mad_decode_field(ni, IB_NODE_PORT_GUID_F, &(guid));
 
                p = ibnd_find_port_guid(fabric, guid);
@@ -758,6 +765,5 @@ int main(int argc, char **argv)
 
 close_port:
        close_node_name_map(node_name_map);
-       mad_rpc_close_port(ibmad_port);
        exit(rc);
 }
--
To unsubscribe from this list: send the line "unsubscribe linux-rdma" in
the body of a message to majord...@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html

Reply via email to