On Mon, Feb 29, 2016 at 09:21:01AM +0000, Ramesh Shanmugasundaram wrote:
> Adds CAN controller nodes for r8a7795.
> 
> Note: CAN channel register base address mentioned in R-Car Gen3 Hardware
> User Manual v0.5E is incorrect. The corrected base addresses are:
> 
> CAN Channel 0 - 0xe6c30000
> CAN Channel 1 - 0xe6c38000
> 
> Signed-off-by: Ramesh Shanmugasundaram 
> <ramesh.shanmugasunda...@bp.renesas.com>

I have deferred this patch pending acceptance of the bindings
(basically patch 1/2). Please repost this patch or ping me once
that has happened.