Hi Simon, On Wed, Mar 23, 2016 at 2:06 AM, Simon Horman <horms+rene...@verge.net.au> wrote: > * Fixed rate and fixed factor clocks do not require an > clock-output-names property. > * Since 07705583e920fef6 ("clk: shmobile: div6: Make clock-output-names > optional") Renesas div6 clocks do not require a clock-output-names > property. > > In the above cases there is only one clock output and its name is taken > from that of the clock node. Accordingly, remove the unnecessary > clock-output-names properties and as necessary update the node names. > > The clock-output-names property is left in place for the zb_clk which is > thus treated as a special case as the MSTP clock driver (clk-mstp.c) > explicitly looks for a clock named zb_clk for the r8a73a4 and sh73a0 SoCs.
... a clock with node name zb_clk ... > Signed-off-by: Simon Horman <horms+rene...@verge.net.au> With the above change: Acked-by: Geert Uytterhoeven <geert+rene...@glider.be> Gr{oetje,eeting}s, Geert -- Geert Uytterhoeven -- There's lots of Linux beyond ia32 -- ge...@linux-m68k.org In personal conversations with technical people, I call myself a hacker. But when I'm talking to journalists I just say "programmer" or something like that. -- Linus Torvalds