Hi Simon,

On Wed, Mar 23, 2016 at 2:06 AM, Simon Horman
<horms+rene...@verge.net.au> wrote:
> * Fixed rate and fixed factor clocks do not require an
>   clock-output-names property.
> * Since 07705583e920fef6 ("clk: shmobile: div6: Make clock-output-names
>   optional") Renesas div6 clocks do not require a clock-output-names
>   property.
>
> In the above cases there is only one clock output and its name is taken
> from that of the clock node.  Accordingly, remove the unnecessary
> clock-output-names properties and as necessary update the node names.
>
> The clock-output-names property is left in place for the zb_clk which is
> thus treated as a special case as the MSTP clock driver (clk-mstp.c)
> explicitly looks for a clock named zb_clk for the r8a73a4 and sh73a0 SoCs.

... a clock with node name zb_clk ...

> Signed-off-by: Simon Horman <horms+rene...@verge.net.au>

With the above change:
Acked-by: Geert Uytterhoeven <geert+rene...@glider.be>

Gr{oetje,eeting}s,

                        Geert

--
Geert Uytterhoeven -- There's lots of Linux beyond ia32 -- ge...@linux-m68k.org

In personal conversations with technical people, I call myself a hacker. But
when I'm talking to journalists I just say "programmer" or something like that.
                                -- Linus Torvalds

Reply via email to